Home - Knowledge - Details

How to judge whether the content of chemical nickel plating solution is within the normal range?

To determine whether the content of chemical nickel plating solution is normal, a combination of chemical analysis, instrument testing, and process verification is required to ensure that each component (nickel ion, reducing agent, complexing agent, pH value, additives, etc.) is within the range of process requirements. The following are specific judgment methods and operation points:
I. Quantitative analysis of key components
1. Nickel ion (Ni²⁺) concentration
Analysis method:
Titration method (most commonly used):
Take a certain volume of plating solution, adjust the pH to 10 with ammonia buffer solution, use ammonium murexate as an indicator, and titrate with EDTA standard solution. The end point is when the solution color changes from yellow to purple.
Normal range: usually 5~12 g/L in acidic plating solution (different processes vary greatly, such as high phosphorus plating solution may be higher).
Instrumental method: atomic absorption spectroscopy (AAS) or inductively coupled plasma optical emission spectroscopy (ICP-OES), suitable for precise measurement or complex plating solution.
Abnormal influence:
Concentration is too low: deposition speed is slow, the coating is thin or there is leakage;
Concentration is too high: it may cause the plating solution to decompose, or the coating to be rough and the phosphorus content to decrease.
2. Concentration of reducing agent (such as sodium hypophosphite, NaH₂PO₂)
Analysis method:
Iodometric method:
Add excess iodine standard solution to the plating solution, and the hypophosphite is oxidized to phosphate;
Titrate the remaining iodine with sodium thiosulfate standard solution, using starch as an indicator, and the disappearance of blue is the end point.
Normal range: usually 20~50 g/L in acidic plating solution, which is proportional to the nickel ion concentration (such as nickel: sodium hypophosphite ≈1:3~1:5).
Potentiometric titration: monitor the change of redox potential through electrodes, suitable for automated analysis.
Abnormal influence:
Concentration is too low: deposition stops or the speed is extremely slow;
Concentration is too high: side reactions are aggravated (such as excessive hydrogen evolution), the stability of the plating solution decreases, and even decomposition occurs.
3. Complexing agent (such as lactic acid, citric acid) concentration
Analysis method:
Acid-base titration method:
Use sodium hydroxide standard solution to titrate the free acid in the plating solution, and calculate the complexing agent content by the amount of base consumed (need to combine the nickel ion concentration to deduct the complexed acid).
Potentiometric titration method: Determine the titration endpoint by the pH mutation point, which is applicable to a variety of complexing agent mixed systems.
Normal range: Need to match the nickel ion concentration, for example, the lactic acid concentration is usually 10~30 g/L (acidic system).
Abnormal influence:
Insufficient concentration: Nickel ions are prone to generate hydroxide precipitation, and the plating solution is turbid or decomposed;
Too high concentration: The complexing ability is too strong, the nickel ion release is slow, and the deposition rate decreases.
4. pH value
Measuring tool: Precision pH test paper or pH meter (needs regular calibration).
Normal range: pH 4.0~5.5 for acidic plating solution, pH 8.0~10.0 for alkaline plating solution (depending on the process).
Abnormal influence:
pH is too high: nickel ions precipitate and the plating solution decomposes;
pH is too low: the decomposition of the reducing agent is accelerated, the deposition rate decreases, and the phosphorus content of the coating increases.
2. Qualitative and semi-quantitative analysis of additives
1. Stabilizers (such as thiourea, lead ions)
Qualitative detection:
Thiourea: Add copper sulfate solution, if an orange precipitate (thiourea-copper complex) is generated, it indicates the presence of thiourea.
Lead ions: Pass hydrogen sulfide gas, if a black precipitate (PbS) is generated, it proves the presence of lead ions.
Semi-quantitative method:
Hull Cell Test: Use a small current to electrolyze the plating solution, observe the appearance of the coating (such as whether there are pinholes, roughness) to determine whether the stabilizer is insufficient or excessive.
2. Surfactant
Detection method:
Foam method: Shake the plating solution vigorously, observe the amount and stability of the foam, and determine whether the surfactant content is appropriate (excessive may cause excessive foam and affect the coating).
Wetting performance test: measure the contact angle of the plating solution on the substrate surface. A contact angle that is too small (<50°) may indicate an excess of surfactant.
3. Impurity ions (such as Fe³⁺, Cu²⁺, Zn²⁺)
Instrumental method: ICP-OES or atomic absorption spectroscopy (AAS) detection. The impurity content usually needs to be controlled at **<10 mg/L** (depending on the process sensitivity).
Chemical method:
Iron ion: Add potassium thiocyanate (KSCN). If the solution turns red, it indicates the presence of Fe³⁺.
Copper ion: Observe the color of the plating solution. If it is blue, it may contain Cu²⁺, which can be verified by electrolysis (low current treatment).
III. Process verification and coating performance test
1. Deposition speed test
Operation method:
Plating on a standard test piece (such as low carbon steel) for 1 hour, measure the coating thickness (such as coulometric thickness gauge or weighing method).
Judgment criteria:
Normal speed: 10~20 μm/h (acidic plating solution). If there is a significant deviation, it may be due to abnormal nickel ions, reducing agents or pH.
2. Appearance and performance of the coating
Visual inspection:
Normal coating: uniform, bright or matte (depending on the process requirements), without pinholes, pitting or peeling.
Abnormal characteristics:
Dark or black: may be excessive stabilizer or impurity contamination;
Rough or granular: may be plating solution decomposition, solid particle suspension or additive imbalance.
Adhesion test:
Cross-cut method (ISO 2409) or bending method, coating shedding may be related to imbalance of plating solution composition (such as insufficient complexing agent leading to large deposition stress).
3. Plating solution stability test
Spontaneous decomposition test:
Heat the plating solution to the process temperature (such as 85~95℃), let it stand and observe whether turbidity or precipitation occurs. Normal plating solution should remain clear for several hours.
Hull cell test:
The stability of the plating solution in a wide potential range can be determined by the state of the plating at different current densities (e.g., burning in the high current area may be due to insufficient additives).
IV. Key points for daily maintenance and control
Establish a standard analysis cycle:
Nickel ions, reducing agents, pH: daily or before each batch of production;
Complexing agents, additives: weekly or per plating solution life cycle (e.g., every 10 cycles);
Impurity ions: monthly or when the plating is abnormal.
Use automatic analysis equipment:
Online pH meter and conductivity meter for real-time monitoring, with automatic refilling system to maintain stable composition.
Standardize the replenishment process:
Avoid adding concentrated solution directly, add slowly after dilution to prevent local components from being too high and causing decomposition.
Record and trend analysis:
Establish a plating solution composition ledger, predict the component consumption trend through historical data, and adjust the replenishment amount in advance.

info-908-902

Send Inquiry

You Might Also Like