How to wire a thermistor?
Leave a message
1. Measure the resistance of three wires with a multimeter. Short circuit the two wires with a resistance of 0 (actually a small resistance value, which is the line resistance used to eliminate the influence of line resistance on the measured value), and connect the other wire to the other end of the measuring instrument.
2. The thermal resistor adopts a three wire connection method. The use of a three wire system is to eliminate measurement errors caused by the resistance of connecting wires. This is because the circuit for measuring thermal resistance is usually an unbalanced bridge. As a bridge arm resistor of the electric bridge, the thermal resistor's connecting wire (from the thermal resistor to the central control room) also becomes a part of the bridge arm resistor. This part of the resistor is unknown and varies with the ambient temperature, causing measurement errors. Adopting a three wire system, one wire is connected to the power terminal of the bridge, and the other two wires are respectively connected to the bridge arm where the thermal resistance is located and the adjacent bridge arm, thus eliminating measurement errors caused by the resistance of the wire line.
Measure the resistance of three wires with a multimeter. The two wires with a resistance of 0 are short circuited (actually a small resistance value, which is the line resistance used to eliminate the influence of line resistance on the measured value), and the other wire is connected to the other end of the measuring instrument.
The three wire system of thermal resistance can be connected
At present, there are three main ways to lead thermal resistors
○ 1 Two wire system: The method of connecting a wire at each end of a thermal resistor to extract a resistance signal is called a two wire system: This lead method is simple, but due to the inevitable lead resistance r in connecting wires, the size of r is related to the material and length of the wire, so this lead method is only suitable for situations with low measurement accuracy
○ 2 Three wire system: The method of connecting a lead at one end of the root of a thermal resistor and two leads at the other end is called the three wire system. This method is usually used in conjunction with an electric bridge and can effectively eliminate the influence of lead resistance. It is a commonly used lead resistance in industrial process control.
○ 3 Four wire system: The method of connecting two wires at each end of the root of the thermistor is called a four wire system, where two leads provide a constant current I to the thermistor, convert R into a voltage signal U, and then lead U to the secondary instrument through the other two leads. It can be seen that this lead method can completely eliminate the influence of lead resistance and is mainly used for high-precision temperature detection.
The thermal resistor adopts a three wire connection method. The use of a three wire system is to eliminate measurement errors caused by the resistance of connecting wires. This is because the circuit for measuring thermal resistance is usually an unbalanced bridge. As a bridge arm resistor of the electric bridge, the thermal resistor's connecting wire (from the thermal resistor to the central control room) also becomes a part of the bridge arm resistor. This part of the resistor is unknown and varies with the ambient temperature, causing measurement errors. Adopting a three wire system, one wire is connected to the power terminal of the bridge, and the other two wires are respectively connected to the bridge arm where the thermal resistance is located and the adjacent bridge arm, thus eliminating measurement errors caused by the resistance of the wire line.