Specification and model of compensating wires and cables for thermocouples
Leave a message
Product Selection: Product Price: 00003000 0 Product Features: The compensating wire series for S-type R-type K-type E-type T-type thermocouples produced by the company is widely used in temperature control systems for energy, metallurgy, petroleum, chemical and other industrial enterprises and research departments. The connection between the cold end of the temperature measuring device and the temperature measuring device. The heat resistant type adopts imported fluoroplastic insulation and sheath, which has excellent heat resistance, waterproof, anti-corrosion, acid and alkali resistance, chemical resistance, abrasion resistance, aging resistance and incombustibility. The operating temperature is -60~260 ℃, which is at the international advanced level. Details of compensating wires and cables for thermocouples: ▲ Execution standard: GB/T4989/94 is applicable to IEC584.3 ▲ Application: Temperature control systems for energy, metallurgy, petroleum, chemical and other industrial enterprises and scientific research departments. The connection between the cold end of the temperature measuring device and the temperature measuring device. The heat resistant type adopts imported fluoroplastic insulation and sheath, which has excellent heat resistance, waterproof, anti-corrosion, acid and alkali resistance, chemical resistance, abrasion resistance, aging resistance and incombustibility. The operating temperature is -60~205 ℃, which is at the international advanced level. ▲ Usage characteristics: Compensation cable usage characteristics
Zui type small bending radius Zui no low temperature Zui high temperature sheath fixed laying non fixed laying general models include:; 105” There are models available; 90” High temperature cable outer diameter 6 times cable outer diameter 10 times cable outer diameter 12 times&ge- 40℃ ≥ - 60℃ ≥ - 15℃ ≥ - 20℃ ≤ 70℃ ≤ 105℃ ≤ 90℃ ≤ 250℃
▲ Product code and meaning:
Item symbol meaning Item symbol name meaning Form SC, using S model thermocouple compensation wire with heat resistance level of 70 degrees Celsius, RC with r model thermocouple compensation wire 105 degrees Celsius, high use temperature of 105 degrees Celsius, NC with n index thermocouple compensation wire 200 degrees Celsius, NX with n index thermocouple compensation wire 250 degrees Celsius, high use temperature 250 degrees Celsius KCA KCB is using k index thermocouple compensation wire insulation material v polyvinyl chloride KX k index thermocouple, It is wire Y, polyethylene compensation EX, E-index thermocouple compensation wire B, polypropylene JX, J-index thermocouple compensation wire F4, polytetrafluoroethylene t, t-index thermocouple compensation wire f6, polyvinyl chloride series wire ZR, flame-retardant cable sheath material v, polyvinyl chloride I a, root safety cable b, glass fiber, classification g, general use F4, polytetrafluoroethylene h, heat-resistant use F46, polyvinyl chloride precision grade s, precision grade shielding material p, copper wire weaving P1, tin plated copper wire weaving/general grade P2 copper tape winding P3, aluminum/plastic composite film winding specification 2 ×; The cross-sectional area of the conductor in mm2 can be omitted for single wire conductors of different types, with a conductor sheath of 22 strands and a steel strip sheath of 32 thin wire sheaths
▲ Technical indicators:
1. Model, insulation color with alloy wire material
Compensation wire form using thermocouple index number compensation wire alloy wire insulation layer color positive level negative SC platinum rhodium 10 platinum thermocouple s SPC (copper) SNC (copper nickel) red green RC rhodium 13 platinum thermocouple RPRC (copper) RNC (copper nickel) red green KCA nickel chromium alloy thermocouple KNCA (iron) KNCA (copper nickel) red blue kcbpcb (copper) KNCB (copper nickel) red blue KX KPX (nickel chromium) KNX (nickel silicon) red black NC nickel silicon thermocouple NNPNC (iron) NNC (copper nickel) red gray NX NPX (nickel chromium) NNX (nickel silicon) red gray EX nickel chromium thermocouple epx (nickel chromium) ENX (copper nickel) red brown JX Iron Copper Nickel Thermocouple JPXXX (Iron) JNX (Copper Nickel) Red Purple TX Copper Copper Nickel Thermocouple tpx (Copper) TNX (Copper Nickel) Red White
2 . Use classified surface colors
Use classification accuracy level and logo sheath color, ordinary level, precision level, ordinary use, g/s, black gray, heat-resistant use, H/s, black yellow
▲ Model name:
Product Model Product Name KXVV PVC Insulation and Sheath for K-Scale Thermocouples Compensation Wire and Cable KXVV22 PVC Insulation and Sheath Steel Strip Sheath for K-Scale Thermocouples Compensation Cable KXVPV PVC Insulation and Sheath Copper Wire Braided Shielding for K-Scale Thermocouples Compensation Wire and Cable KXVPV PVC Insulation and Sheath Copper Wire Braided Shielding Steel Strip Sheath for K-Scale Thermocouples Compensation Cable KXVVP PVC Insulation and Sheath Copper Wire Braided Shielding for K-Scale Thermocouples Compensation Cable KXVV22P PVC Insulation and Protective Sheath Copper Wire Braided Overall Shielding Steel Strip Sheath for K-Scale Thermocouples General Grade K-Size Number Thermocouple Cable KXVPVP PVC Insulation and Sheath Copper Wire Braided Partial Shielding and Overall Shielding General Grade K-Size Number Thermocouple Use compensating cable KXVPV22 PVC insulation and sheath Copper wire braided shielding and total shielding, steel tape sheath, K-size compensation cable for thermocouples, KXFF fluororesin and sheath, compensation wire for general signal thermocouples, cable KXFPF fluororesin, sheath copper wire braided part shielding, general grade K-grade compensation wire for thermocouples, cable KXFFP fluoroplastic, sheath copper wire braided total shielding, general grade K-grade compensation wire for thermocouples, cable KXFPFP fluororesin, sheath copper wire braided part shielding and total shielding, general grade k
▲ Formal description:
Classification Code Block Burning Code Condemnation Burning Series Number X/c Sheath Material Polyvinyl Chloride v Flame Retardant ZR Insulation Material Fluororesin f Low Smoke Low Halogen Polyvinyl Chloride VD Grade a Flame Retardant ZA Polyvinyl Chloride v Low Smoke Zero Halogen Polyolefin e Grade b Flame Retardant ZB Low Smoke Low Halogen Polyvinyl Chloride VD Fluororesin f Grade c Flame Retardant ZC Low Smoke Zero Halogen Polyolefin e Heat Resistant 70 Omitting Shielded Copper Wire/Tin Plated p Sheath Steel Strip Sheath 22 105 ℃, 90 ℃ 90 Copper Strip/Copper Mold P2 Fine Wire Bundle 32 105 ℃ 105 Aluminum Strip/Aluminum P3/P1 Safety Cable IA 205 ℃ FF
▲ Specifications:
Cross section (mm2) Conductor diameter (mm) Logarithmic range Core number range Special limitation: 0.5 1/0.80 or 7/0.301, 2, 3~24 When the number of cores is less than 4 pairs, no sheath is required. 0.75 1/0.97 or 7/0.37 1.0 1/1.13 or 7/0.43 1.5 1/1.38 or 7/0.52.5/1.78 or 7/0.68
▲ Delivery length: Cables are generally over 100 meters long and can be delivered in short lines of over 10 meters. Quantity not exceeding 10% of the total delivery length, measurement error≤ ± 5%. If there are special requirements, the supply and demand parties can negotiate separately.
Product related keywords: compensating wires for thermocouples, specifications and models of compensating cables. Selection instructions for compensating wires and cables for thermocouples.