12 Zone Hot Sale Thermocouple K Injection Mould Temperature Controller
UATC-20 The UATC-20 HRTC Hot Runner Temperature Controller is an advanced and fully microprocessor based module designed for Hot Runner Mold Temperature Control applications. The unique circuitry of the UATC-20 results in a rugged, dependable and simple to operate unit. The UATC-20’s...
Description
1. General Specifications
|
Power Supply
|
1-phase 3-wire, 240Vac, 50/60Hz
3-phase 4-wire, 240Vac, 50/60Hz
3-phase 5-wire, 380Vac, 50/60Hz
|
Mainframe
|
Blue & white
|
|
Control Module
|
HRTC-G
|
||
|
Sensor Type
|
Thermocouple J or K
|
Module Qt'y
|
12
|
|
Temperature Control
|
0~450℃(32~842℉)
|
Control Mode
|
Auto-PID / Manual
|
|
Output Type
|
Zero Cross / Phase Angle
|
Control Accuracy
|
±0.1%F.S
|
|
Connector Type
|
Customized
|
Load Capacity
|
15A, 3600W
|
|
Wiring Mode
|
Customized
|
Storage Temperature
|
-20~70℃(-4~158℉)
|
|
Working Temperature
|
0~55℃(32~131℉)
|
Working Humidity
|
10~80%RH(No condensing)
|
2. Features
Light handy and easy to use
• Wide power supply range, AC85~400V
• There are 2, 4, 6, 8, 10, 12, 24 zones for customers to select.
• Thermocouple input protection, prevent module damaged by mis-connection
• Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
• Soft-start mode, avoid the humidity make the heater burn out
• Compatible with YUDO, Athena, DME, PCS, INCOE, etc.
• Soft-start mode, avoid the humidity make the heater burn out
• Compatible with YUDO, Athena, DME, PCS, INCOE, etc.
Alarm when the followings occurred
1. Ultra-high or ultra-low Temperature
2. Thermocouple break, short or inverse
3. Thermocouple is out of its position
4. Heater break, short or overload
5. Output device is damaged
2. Thermocouple break, short or inverse
3. Thermocouple is out of its position
4. Heater break, short or overload
5. Output device is damaged
6. Over voltage of power supply
Protection activated in the following situations:
1. Over voltage self-protectd, max.AC500V
2. Thermocouple input protection, prevent module damaged by misconnection
3. Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
4. Soft-start mode, avoid the moisture make the heater burn out
5.Heater dehumidified time can be extended
|
Features
|
HRTC-A
|
HRTC-B
|
HRTC-G
|
|
Zone
|
Single zone
|
single zone
|
Single zone
|
|
Process Display
|
LED
|
LED
|
LCD
|
|
Sensor Type
|
Thermocouple J or K
|
||
|
Power Switch
|
Pushbutton
|
Toggle switch
|
Pushbutton
|
|
Control Mode
|
Auto PID or Manual
|
||
|
Control Accuracy
|
±0.1%F.S
|
±0.1%F.S
|
±0.1%F.S
|





Send Inquiry
You Might Also Like
-

Incubator Controller Modbus Thermostat Temperature I...
-

Hot Runner Temperature Control Box Using For Plastic...
-

HRTC Hot Runner Temperature Controller
-

Plastic Injection Hot Runner Temperature Controller
-

Temperature Controller Hot Runner Temperature Box
-

High Precision Manual Hot Runner Thermo Controller