How to burn carbon black in a multi-purpose furnace?
Leave a message
How do you burn carbon black in a multi-purpose furnace? Here's a guide from a multi-purpose furnace production line manufacturer:
1. Lower the furnace temperature to 820-850°C.
2. When the furnace temperature stabilizes, open the front door.
3. Turn off the carbon potential control, close the methanol and propane shutoff valves, close the nitrogen shutoff valve, and stop the back chamber gas supply.
4. Turn off the carbon potential control, close the safety nitrogen shutoff valve, and stop the back chamber gas supply.
5. Open the middle door 50-100mm and hold for approximately two hours before beginning the carbon black burn. During the burn, pay attention to the furnace temperature. If the furnace temperature rises too quickly, exceeding 880°C, close the middle door and wait until the temperature returns to normal before opening it again. (Carbon black can also be burned without opening the middle door; stopping the back chamber gas supply for four to six hours will achieve the same effect.)
6. After the carbon black burn is complete, close the middle door.
7. Turn on the safety nitrogen gas, controlling the flow rate at 3-5 m³/h.
8. Turn on the "Gas Supply On" button and proceed to the next step according to the air-carburizing procedure.
Note: Large amounts of carbon black deposits in the furnace can disrupt the carburizing process, affect the stability of carbon potential control, hinder heat transfer within the heating elements, and reduce the service life of furnace components. If significant carbon deposits form in the furnace, they must be burned promptly. It is recommended to burn the carbon black approximately every three weeks. If the rate of carbon black accumulation is rapid, the burnout period should be shortened. Furnace Shutdown:
1. End the multi-purpose furnace cycle and unload the workpiece.
2. Open the front door.
3. Turn off the gas supply. Close the methanol and propane shutoff valves.
4. Generally, carbon black burnout can be considered during furnace shutdown. Even if carbon black is not being burned, the center door should be opened 50-100mm for a period of time to eliminate any combustible atmosphere within the furnace.
5. For short-term furnace shutdowns, it is recommended to lower the furnace temperature to 800°C for insulation. For extended shutdowns, turn off the heating control. 6. When the furnace temperature drops below 400°C, close the safety nitrogen shutoff valve, close all process medium main control valves, and remove the red elbow in the gas supply line (if the furnace has been shut down for an extended period).
7. When the furnace temperature drops below 200°C, turn off the inverter power, shut off the front and rear chamber circulation fans, shut off the oil cooling pump and fan, and turn off the main power switch.
The above is a summary of the multi-purpose furnace heat treatment process. I hope it will be helpful.