Multi-purpose furnaces are primarily used for the carburizing and quenching of products. The production process involves automated production following a pre-programmed process. While temperature can be measured directly by thermocouples, the carbon potential of the atmosphere cannot be directly measured. Instead, its value is calculated from multiple parameters. Parameter variations can lead to significant deviations between the measured and actual carbon potential, potentially causing uncontrolled carbon potential within the furnace and seriously threatening product quality.

The gas carburizing atmosphere is typically composed primarily of N₂COH₂, with trace amounts of CO₂H₂OO₂CH₄, among others. At high temperatures, these gases undergo various chemical reactions with the steel and its carbides, and certain chemical reactions also occur among the various gases themselves. As you can imagine, the reactions involved are extremely complex, requiring detailed analysis for effective atmosphere control. If a multi-furnace heat treatment is used for carburizing, regardless of the process used, the metallographic structure shows a high carbon potential. For example, if a carbon potential of 1.05 is used for carburizing at 920°C for 180 minutes, followed by diffusion at 0.85 for 80 minutes, and quenching at 840°C for 30 minutes, the carbide is grade 6. Carburizing the furnace four times a week has no noticeable effect. Cleaning and carburizing the oxygen head also failed to resolve the issue.

What is the core cause?

Using an analyzer for auxiliary measurements revealed three possible causes:

1. The oxygen probe cycle has expired.

2. If the oxygen probe is normal, adjust the CO setting to within the range specified by the process parameters.

3. Check the enrichment gas flow rate to ensure it does not exceed the specified range.

4. Adjust the CO setting to ensure that the actual carbon potential in the furnace matches the instrument display.

Conclusion: In production, it is necessary to regularly measure the actual carbon potential of the equipment atmosphere based on product quality and adjust the carbon control instrument settings accordingly to ensure that the instrument's calculated value truly reflects the actual carbon potential of the atmosphere.

When calculating the carbon potential value, the instrument assumes that the atmospheric CO concentration is constant. However, the CO concentration in the equipment atmosphere is not always a constant value. When judging that the CO concentration in the equipment atmosphere fluctuates, it is necessary to have a more accurate judgment on the carbon potential value of the atmosphere, and not blindly believe in the value calculated by the instrument, otherwise it may endanger the quality of the product in the furnace.