How to maintain the pusher furnace can be used for a longer time

1. Before using the atmosphere pusher furnace, you must carefully read the operating instructions of the relevant products and operate in accordance with the operating instructions.

2. When using or reusing after long-term storage, the atmosphere pusher furnace should be oven operated. The specific steps are as follows: the oven time should be at room temperature 200℃ for four hours and 200℃ to 600℃ for four hours.

3. In actual operation, the maximum furnace temperature of the atmosphere pusher furnace should not exceed the rated temperature, so as not to destroy the electric heating elements and affect the normal use of the electric furnace in the later period.

4. It is strictly forbidden to pour various liquids and easily soluble metals into the electric furnace, and work at a temperature below 50°C below the maximum temperature. At this time, the furnace wire has a longer life.

5. Atmosphere pusher furnace electric furnace controller should be limited to use in the ambient temperature range of -10 to 75 ℃.

6. Clean the hearth of the atmosphere pusher furnace on a regular basis to remove oxides and other substances in the electric furnace in time.