Home - Knowledge - Details

K-type thermocouple compensation wire and KX compensation cable

Compensation wire and KX compensation cable for K-type thermocouple

Scope of application:
Compensation wire and compensation cable are one or more pairs of wires or cables with J insulation layer that have the same thermoelectric potential as the matched thermocouple within a certain temperature range (including normal temperature). They are used to connect thermocouples and measuring devices to compensate for the errors caused by temperature changes at the connection between them and the thermocouples. Compensation wire and compensation cable are divided into extension and compensation types.
Use characteristics of compensation wire and KX compensation cable for K-type thermocouple:

Working temperature heat-resistant use: high 180℃, 200℃ and 260℃. General use: high 70℃, 90℃ and 105℃

Long-term allowable ambient high working temperature of cable:

PVC sheath: 70℃, 90℃ and 105℃. Silicone rubber sheath does not exceed: 180℃. Fluoroplastic sheath does not exceed 200℃. PFA sheath does not exceed 260℃.

The laying temperature of the cable should not be lower than:

Fixed laying -60℃. Non-fixed installation -20℃

2. Recommended allowable bending radius: Fluoroplastic sheathed cables and armored cables should be no less than 12 times the outer diameter of the cable
PVC sheathed cables should be no less than 10 times the outer diameter of the cable

Basic models and M names KX-FF46-RP1 KX-HA-FFRP KX-GA-VV KX-HA-FGR

1: Compensation wire for thermocouple

KX-GA-VV

PVCJ-insulated PVC sheathed accurate K-grading thermocouple compensation wire

KX-GA-VVR

PVCJ-insulated PVC sheathed accurate K-grading thermocouple compensation soft wire

KX-GA-VVP

PVCJ-insulated PVC sheathed copper wire braided shielded accurate K-grading thermocouple compensation wire

KX-GA-VVRP

PVCJ-insulated PVC sheathed copper wire braided shielded accurate K-grading thermocouple compensation soft wire

KX-HA-FF

Fluoroplastic J-insulated and sheathed accurate K-grading thermocouple compensation Conductor
KX-HA-FFR

Fluoroplastic J-edge and sheath accurate K-grading thermocouple compensation soft conductor
KX-HA-FFP

Fluoroplastic J-edge and sheath copper wire braided shield accurate K-grading thermocouple compensation soft conductor
KX-HA-FFRP

Fluoroplastic J-edge and sheath copper wire braided shield accurate K-grading thermocouple compensation soft conductor
KX-HA-FG

Fluoroplastic J-edge silicone rubber sheath accurate K-grading thermocouple compensation soft conductor
KX-HA-FGR

Fluoroplastic J-edge silicone rubber sheath accurate K-grading thermocouple compensation soft conductor
KX-HA-FGP

Fluoroplastic J-edge silicone rubber sheath copper wire Braided shield accurate K-grade thermocouple compensation wire
KX-HA-FGRP

Fluoroplastic J-edge silicone rubber sheath copper wire braided shield accurate K-grade thermocouple compensation soft wire
KX-HA-FV

Fluoroplastic J-edge PVC sheath accurate K-grade thermocouple compensation wire
KX-HA-FVR

Fluoroplastic J-edge PVC sheath accurate K-grade thermocouple compensation soft wire
KX-HA-FVP

Fluoroplastic J-edge PVC sheath copper wire braided shield accurate K-grade thermocouple compensation wire
KX-HA-FVRP

Fluoroplastic J-edge PVC sheath copper wire braided shield accurate K-grade thermocouple Compensation soft wire
KX-GA-YJV

Cross-linked polyethylene J-insulation PVC sheath accurate K-grading thermocouple compensation wire
KX-GA-YJVR

Cross-linked polyethylene J-insulation PVC sheath accurate K-grading thermocouple compensation soft wire
KX-GA-YJVP

Cross-linked polyethylene J-insulation PVC sheath copper wire braided shield accurate K-grading thermocouple compensation wire
KX-GA-YJVRP

Low smoke zero halogen J-insulation and sheath copper wire braided shield accurate K-grading thermocouple compensation soft wire
KX-GA-YDYD

Low smoke zero halogen J-insulation and sheath accurate K-grading thermocouple compensation wire
KX-GA- YDYD R

Low smoke halogen-free J-insulation and sheathed accurate K-grading thermocouple compensation soft wire
KX-GA- YDYD P

Low smoke halogen-free J-insulation and sheathed copper wire braided shielded accurate K-grading thermocouple compensation soft wire
KX-GA- YDYD RP

Low smoke halogen-free J-insulation and sheathed copper wire braided shielded accurate K-grading thermocouple compensation soft wire
Note: The above model only lists KX, and others such as SC, KC, EX, BC, TX, and JX only need to change the model item.
Add ZR before the flame-retardant compensation wire model. ZR192 is made of PFA material.

The shield can be shielded with tinned copper wire.

 

 

 

info-2245-1547