1. If the single head pipe is used for a long time and there is a thick accumulation of pipe scale and oil scale on the surface, it should be removed regularly, otherwise it will reduce the heat transfer performance of the single head pipe and cause the surface heat load of the pipe to exceed the rated allowable limit and be damaged.

2. The heating part of the single head tube should be fully immersed in the heating medium to avoid rapid heat dissipation that exceeds the allowable heating temperature and causes damage to the single head tube. In addition, the wiring outlet should be exposed outside the insulation layer or heater to prevent overheating and damage.

3. The wiring terminals of single ended pipes should be kept clean and dry. Otherwise, it will reduce insulation performance and be short circuited and broken down. If used in environments with chemical corrosion, flammable, explosive liquids or gases, the wiring part of single ended pipes should be tightly protected with insulation sealing devices to prevent accidents.

Single head electric heating tube manufacturer

4. When heating certain substances such as adhesives, such as sodium nitrate, stearic acid, paraffin, etc., the power supply voltage should be reduced at the beginning of heating to reduce the heat generation of the single head tube. When all of them are melted into liquid, they should be raised to the rated voltage for heating.

5. The input power supply should not exceed 10% of the rated voltage indicated on various single headed tubes. If applied below the rated voltage, the heat generated by the single headed tube will also decrease.

6. Special single headed pipes should carefully read the relevant instructions before installation and use to avoid damage.

7. When connecting single ended pipes, two nuts should be tightened relative to each other. Do not apply too much force to avoid loosening the screws and damaging the single ended pipes.

8. Special attention should be paid to the heating medium when selecting a single headed tube. There should be no corrosive effect on the single head shell material.

9. Single headed pipes should be stored in a dry warehouse. If the surface is damp due to long-term storage, a megohmmeter should be used to measure the insulation resistance before use. If it is less than 1 megaohm/500 volts, the single ended tube should be dried in a 200 degree drying oven.

1. When connecting the heating tube terminals, two nuts should be tightened relative to each other. Do not apply too much force to avoid loosening the screws and damaging the heating tube.

2. Heating tubes should be stored in a dry warehouse. If the surface is damp due to long-term storage, a megohmmeter should be used to measure their insulation resistance during use. If it is less than 1 megaohm/500 volts, the electric heating tube should be placed in a 200 degree drying oven for drying.

3. The heating part of the heating tube should be fully immersed in the heating medium to avoid rapid heat dissipation that exceeds the allowable heating temperature and causes damage to the electric heating tube. In addition, the wiring outlet should be exposed outside the insulation layer or heater to prevent overheating and damage.

4. The input power supply should not exceed 10% of the rated voltage indicated on various electric heating tubes. If it is lower than the rated voltage, the heat generated by the heating tube will also decrease.